Completed Intelligent Conventional 4/8/16 Zones Control Panel Fire Alarm System
Basic Info
Model NO. | SR-P01-4 |
Type | Fire Alarm Control Panel |
Color | Red |
Fire Panel Type | Conventional |
Zone Number | 4 Zone, 8 Zone, 16 Zone Optional |
Net Weight | 10kg |
AC Power | 220VAC, 50 Hz. |
Maximum Battery Charger Capacity | 18ah Battery |
Total DC24V System Power | 3.0 AMPS |
Non-Resettable Power Output. | Yes |
Transport Package | Carton |
Specification | 220VAC, 50 Hz. |
Trademark | SUMRING |
Origin | China |
HS Code | 8531901000 |
Production Capacity | 5000 PCS/Month |
Product Description
Completed intelligent Conventional 4/8/16 zones control panel Fire Alarm System
Product Description
Fire alarm control panel:SR-P01-4 4 zones conventional fire alarm control panelSR-P01-8 8 zones conventional fire alarm control panelSR-P01-16 16 zones conventional fire alarm control panel
Main features:
Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accepttwo-wire smoke detectors and any normally-open contact devices.Two Supervisory Input with DC12V output, ideal to connect security alarm devices.Three General Alarm, Trouble and Supervisory, Form A Relay Output.One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits(NACs), NACs may be programmed: Silenceable or Non-Silenceable.3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output.Zone Input Short Circuit can be set to "Alarm" or " Fault" mode.RS485 Communication Port (optional).Automatic/Manual mode can be programmed.Disable/Enable control per Zone (IDC) can be programmed.Disable/Enable Sound Output(NACs) can be programmed.
Technical Parameters
AC Power | 220VAC, 50 Hz. |
Battery | Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge |
Maximum battery charger capacity | 18AH battery |
NOTE | Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box |
Total DC24V system power | 3.0 amps |
Maximum current per NAC | 1.25 amps |
Resettable four-wire smoke detector power output. | yes |
Non-resettable power output. | yes |
Integral Form-A Alarm, Trouble and Supervisory relays, rated at | 2.0 amps @ 30 VDC(resistive), 2.0 amps @ 30 VAC (resistive) |
Product show:
This fire alarm control panel can Match any 2/4-wire smoke heat detector,strobe siren,fire bell,manual call point ect
smoke detector | 2 wire, 4 wire optiona, photoeletrci type |
heat detector | 2 wire, 4 wire optional, rate of rise or fixed temeparture |
strobe siren | wired type, with or without strobe |
fire bell | wired type, indoor or outdoor type |
manual call point | resettable type or breaking glass type optional |
Not only the alarm control panel we have, but also we offer all kinds of detectors you want, we are looking forward to your inquiry, thank you!
more info :https://cnsumring.en.made-in-china.com/